§204-1.1 Purpose and authorization to the administrator
This Part establishes the New York State component of the NOx Budget Trading Program which is designed to mitigate the interstate transport of ozone and nitrogen oxides, an ozone precursor. The department authorizes the administrator to assist the department in implementing the NOx Budget Trading Program by performing the functions set forth for the administrator in this Part.
§204-1.2 Definitions
(a) To the extent that they are not inconsistent with the specific definitions in subdivision (b) of this section, the general definitions of Part 200 of this Title apply to this Part.
(b) For the purposes of this Part, the following specific definitions apply:
(1) Account certificate of representation. The completed and signed submission required by Subpart 204-2 of this Part for certifying the designation of a NOx authorized account representative for a NOx budget source or a group of identified NOx budget sources who is authorized to represent the owners and operators of such source or sources and of the NOx budget units at such source or sources with regard to matters under the NOx Budget Trading Program.
(2) Account number. The identification number given by the administrator to each NOx allowance tracking system account.
(3) Acid rain emissions limitation. As defined in 40 CFR 72.2, a limitation on emissions of sulfur dioxide or nitrogen oxides under the Acid Rain Program under title IV of the act.
(4) Allocate or allocation. The determination by the department of the number of NOx allowances to be initially credited to a NOx budget unit or an allocation set-aside.
(5) Annual average heat rate. A measure of an electricity generating unit's thermal efficiency, expressed in Btu's per net kilowatt-hour, computed by dividing the heat input (based on total higher heating value Btu content of the fuel burned) for electricity generation by the resulting net kilowatt-hour generation during a calendar year. For co-generation facilities, the heat input for electricity generation is calculated by the sum of the heat input for combustion turbines, steam boilers (excluding backup boilers) and supplemental firing minus the net heat input of useful thermal energy provided for purposes other than electricity generation.
(6) Automated data acquisition and handling system or DAHS. That component of the CEMS, or other emissions monitoring system approved for use under Subpart 204-8 of this Part, designed to interpret and convert individual output signals from pollutant concentration monitors, flow monitors, diluent gas monitors, and other component parts of the monitoring system to produce a continuous record of the measured parameters in the measurement units required by Subpart 204-8 of this Part.
(7) Boiler. An enclosed fossil or other fuel-fired combustion device used to produce heat and to transfer heat to recirculating water, steam, or other medium.
(8) Combined cycle system. A system comprised of one or more combustion turbines, heat recovery steam generators, and steam turbines configured to improve overall efficiency of electricity generation or steam production.
(9) Combustion turbine. An enclosed fossil or other fuel-fired device that is comprised of a compressor (if applicable), a combustor, and a turbine, and in which the flue gas resulting from the combustion of fuel in the combustor passes through the turbine, rotating the turbine.
(10) Commence commercial operation. With regard to a unit that serves a generator, to have begun to produce steam, gas, or other heated medium used to generate electricity for sale or use, including test generation. For a unit that is a NOx budget unit under section 204-1.4 of this Subpart on the date the unit commences commercial operation, such date shall remain the unit's date of commencement of commercial operation even if the unit is subsequently modified, reconstructed, or repowered. Except as provided in Subpart 204-9 of this Part, for a unit that is not a NOx budget unit under section 204-1.4 of this Subpart on the date the unit commences commercial operation, the date the unit becomes a NOx budget unit under section 204-1.4 of this Subpart shall be the unit's date of commencement of commercial operation.
(11) Commence operation. To have begun any mechanical, chemical, or electronic process, including, with regard to a unit, start-up of a unit's combustion chamber. For a unit that is a NOx budget unit under section 204-1.4 of this Subpart on the date of commencement of operation, such date shall remain the unit's date of commencement of operation even if the unit is subsequently modified, reconstructed, or repowered. Except as provided in Subpart 204-9 of this Part, for a unit that is not a NOx budget unit under section 204-1.4 of this Subpart on the date of commencement of operation, the date the unit becomes a NOx budget unit under section 204-1.4 of this Subpart shall be the unit's date of commencement of operation.
(12) Common stack. A single flue through which emissions from two or more units are exhausted.
(13) Compliance account. A NOx allowance tracking system account, established by the administrator for a NOx budget unit under Subpart 204-6 of this Part, in which the NOx allowance allocations for the unit are initially recorded and in which are held NOx allowances available for use by the unit for a control period for the purpose of meeting the unit's NOx budget emissions limitation.
(14) Compliance certification. A submission to the department or the administrator, as appropriate, that is required under Subpart 204-4 of this Part to report a NOx budget source's or a NOx budget unit's compliance or noncompliance with this Part and that is signed by the NOx authorized account representative in accordance with Subpart 204-2 of this Part.
(15) Continuous emission monitoring system or CEMS. The equipment required under Subpart 204-8 of this Part to sample, analyze, measure, and provide, by readings taken at least once every 15 minutes of the measured parameters, a permanent record of nitrogen oxides emissions, expressed in tons per hour for nitrogen oxides. The following systems are component parts included, consistent with 40 CFR part 75, in a continuous emission monitoring system:
(i) flow monitor;
(ii) nitrogen oxides pollutant concentration monitors;
(iii) diluent gas monitor (oxygen or carbon dioxide) when such monitoring is required by Subpart 204-8 of this Part;
(iv) a continuous moisture monitor when such monitoring is required by Subpart 204-8 of this Part; and
(v) an automated data acquisition and handling system.
(16) Control period. The period beginning May 1st of a year and ending on September 30th of the same year, inclusive.
(17) CPPTE or control period potential to emit. The maximum capacity of a NOx budget unit to emit NOx under its physical and operational design during a control period. Any physical or operational limitation on the capacity of a NOx budget unit to emit NOx, including air pollution control equipment and/or a restriction on the hours of operation, or on the type or amount of material combusted shall be treated as part of the design if the limitation is enforceable by the department and the administrator.
(i) For electricity generating units and non-electricity generating units, the CPPTE can be no greater than the number to be determined by the following:
CPPTE < [5/12thsABUhr × BUER) + (3,672 = 5/12thsABUhr) × PER)] × MRHHI when PER and BUER are in pounds per million Btu; or,
CPPTE < [5/12thsABUhr × BUER) + (3,672 = 5/12thsABUhr) × PER)] × PER and BUER are in pounds per hour,
where:
"ABUhr" is number of hours it takes annually to combust the quantity of the backup fuel allowed under the unit's permit which, if used as the only fuel for the unit, would be the number of hours in determining the emission rate potential for the unit.
"BUER" is the lowest emission rate applicable to the use of the backup fuel (in pounds per million Btu or pounds per hour based on inlet temperature of 47.5° F) allowed under the unit's permit which, if used as the only fuel for the unit, would be the emission rate in determining the emission rate potential for the unit.
"PER" is the lowest emission rate applicable to the use of the primary fuel (in pounds per million Btu or pounds per hour based on inlet temperature of 47.5° F) allowed under the unit's permit.
"MRHHI" is the maximum rated hourly heat input for the unit based upon an inlet air temperature of 47.5° F for those units without temperature control.
(ii) For portland cement kiln units, the CPPTE can be no greater than the number to be determined by the following:
CPPTE < 3,672 × ER
where:
"ER" is the lowest applicable emission rate (in pounds per hour) allowed under the unit's permit.
(18) End use energy efficiency project. A measure implemented at the customer level that uses a reduced
amount of electricity, measured in kilowatt-hours to maintain or increase the level of energy service, including product output and comfort level. Examples of such a measure include, without limitation, installing new equipment or systems, modifying existing equipment or systems, or improving operation and maintenance procedures.
(19) Energy Information Administration. The Energy Information Administration of the United States Department of Energy.
(20) Excess emissions. Any tonnage of nitrogen oxides emitted by a NOx budget unit during a control period that exceeds the NOx Budget emissions limitation for the unit.
(21) Fossil fuel. Natural gas, petroleum, coal, or any form of solid, liquid, or gaseous fuel derived from such material.
(22) Fossil fuel-fired. With regard to a unit: the combustion of fossil fuel, alone or in combination with any other fuel, where the fossil fuel combusted comprises, or is projected to comprise, more than 50 percent of the annual heat input on a Btu basis during any year; provided that the unit shall be fossil fuel-fired as of the date, during such year, on which the unit begins combusting fossil fuel.
(23) General account. A NOx allowance tracking system account, established under Subpart 204-6 of this Part, that is not a compliance account or an overdraft account.
(24) Generator. A device that produces electricity.
(25) Heat input. The product (in mmBtu/time) of the gross calorific value of the fuel (in Btu/lb) and the fuel feed rate into a combustion device (in mass of fuel/time), as measured, recorded, and reported to the administrator by the NOx authorized account representative and as determined by the administrator in accordance with Subpart 204-8, and does not include the heat derived from preheated combustion air, recirculated flue gases, or exhaust from other sources.
(26) Higher heating value heat content. Total gross calorific value of the fuel, or the total heat (in Btu/specified unit of fuel) produced when the fuel is completely combusted under standardized conditions, including the heat lost in the vaporization of water contained in the fuel.
(27) In-plant efficiency measure. A measure undertaken at a NOx budget source that increases the overall energy efficiency of the facility. Examples of such a measure include, without limitation, improvements in thermal efficiency, more efficient production of electricity, or more efficient production of cement (or clinker).
(28) Life-of-the-unit, firm power contractual arrangement. A unit participation power sales agreement under which a utility or industrial customer reserves, or is entitled to receive, a specified amount or percentage of nameplate capacity and associated energy from any specified unit and pays its proportional amount of such unit's total costs, pursuant to a contract:
(i) for the life of the unit;
(ii) for a cumulative term of no less than 30 years, including contracts that permit an election for early termination; or
(iii) for a period equal to or greater than 25 years or 70 percent of the economic useful life of the unit determined as of the time the unit is built, with option rights to purchase or release some portion of the nameplate capacity and associated energy generated by the unit at the end of the period.
(29) Long dry kiln. A kiln 14 feet or larger in diameter, 400 feet or greater in length, which employs no preheating of the feed. The inlet feed to the kiln is dry.
(30) Long wet kiln. A kiln 14 feet or larger in diameter, 400 feet or greater in length, which employs no preheating of the feed. The inlet feed to the kiln is a slurry.
(31) Maximum clinker production. The ability of a portland cement kiln to produce a stated maximum amount of clinker per hour on a steady state basis, as determined by the physical design and physical characteristics of the kiln.
(32) Maximum design heat input. The ability of a unit to combust a stated maximum amount of fuel per hour on a steady state basis, as determined by the physical design and physical characteristics of the unit.
(33) Maximum potential hourly heat input. An hourly heat input used for reporting purposes when a unit lacks certified monitors to report heat input. If the unit intends to use appendix D of 40 CFR part 75 to report heat input, this value should be calculated, in accordance with 40 CFR part 75, using the maximum fuel flow rate and the maximum gross calorific value. If the unit intends to use a flow monitor and a diluent gas monitor, this value should be reported, in accordance with 40 CFR part 75, using the maximum potential flowrate and either the maximum carbon dioxide concentration (in percent CO2) or the minimum oxygen concentration (in percent O2).
(34) Maximum potential NOx emission rate. The emission rate of nitrogen oxides (in lb/mmBtu) calculated in accordance with section 3 of appendix F of 40 CFR part 75, using the maximum potential nitrogen oxides concentration as defined in section 2 of appendix A of 40 CFR part 75, and either the maximum oxygen concentration (in percent O2) or the minimum carbon dioxide concentration (in percent CO2), under all operating conditions of the unit except for unit start up, shutdown, and upsets.
(35) Maximum rated hourly heat input. Except as found at paragraph (17) of this subdivision, a unit-specific maximum hourly heat input (in mmBtu) which is the higher of the manufacturer's maximum rated hourly heat input or the highest observed hourly heat input.
(36) Monitoring system. Any monitoring system that meets the requirements of Subpart 204-8 of this Part, including a continuous emissions monitoring system, an excepted monitoring system, or an alternative monitoring system.
(37) Most stringent State or Federal NOx emissions limitation. With regard to a NOx budget opt-in unit, the lowest NOx emissions limitation (in terms of lb/mmBtu) that is applicable to the unit under State or Federal law, regardless of the averaging period to which the emissions limitation applies.
(38) Nameplate capacity. The maximum electrical generating output (in MWe) that a generator can sustain over a specified period of time when not restricted by seasonal or other deratings as measured in accordance with the United States Department of Energy standards.
(39) Net kilowatt-hour generation. Gross generation minus the plant use of electricity or all electricity supplied to the electric power grid. For co-generation facilities, all electricity supplied to the electric power grid, the host site and other industrial and commercial customers, but excluding electricity used by the co-generation facility and fuel handling and processing equipment.
(40) New York State Trading Program budget. The total number of NOx tons apportioned to all NOx budget units in New York State, in accordance with the NOx Budget Trading Program, for use in a given control period.
(41) NOx allowance. An authorization by the department under the NOx Budget Trading Program to emit up to one ton of nitrogen oxides during the control period of the specified year or of any year thereafter.
(42) NOx allowance deduction or deduct NOx allowances. The permanent withdrawal of NOx allowances by the Administrator from a NOx allowance tracking system compliance account or overdraft account to account for the number of tons of NOx emissions from a NOx budget unit for a control period, determined in accordance with Subpart 204-8 of this Part, or for the forfeit of NOx allowances as provided by this Part.
(43) NOx allowances held or hold NOx allowances. The NOx allowances recorded by the administrator, or submitted to the administrator for recordation, in accordance with Subparts 204-6 and 204-7 of this Part, in a NOx allowance tracking system account.
(44) NOx allowance Tracking System. The system by which the administrator records allocations, deductions, and transfers of NOx allowances under the NOx Budget Trading Program.
(45) NOx allowance tracking system account. An account in the NOx allowance tracking system established by the administrator for purposes of recording the allocation, holding, transferring, or deducting of NOx allowances.
(46) NOx allowance transfer deadline. Midnight of November 30th or, if November 30th is not a business day, midnight of the first business day thereafter and is the deadline by which NO x allowances may be submitted for recordation in a NOx budget unit's compliance account, or the overdraft account of the source where the unit is located, in order to meet the unit's NOx budget emissions limitation for the control period immediately preceding such deadline.
(47) NOx authorized account representative. For a NOx budget source or NOx budget unit at the source, the natural person who is authorized by the owners and operators of the source and all NOx budget units at the source, in accordance with Subpart 204-2 of this Part, to represent and legally bind each owner and operator in matters pertaining to the NOx Budget Trading Program or, for a general account, the natural person who is authorized, in accordance with Subpart 204-6 of this Part, to transfer or otherwise dispose of NOx allowances held in the general account.
(48) NOx budget emissions limitation. For a NOx budget unit, the tonnage equivalent of the NOx allowances available for compliance deduction for the unit for a control period.
(49) NOx budget opt-in permit. A NOx budget permit covering a NOx budget opt-in.
(50) NOx budget opt-in unit. A unit that has been elected to become a NOx budget unit and whose NOx budget opt-in permit has been issued and is in effect under Subpart 204-9 of this Part.
(51) NOx budget permit. The portion of the legally binding and federally enforceable written permit issued by the department pursuant to Part 201 of this Title to a NOx budget source or NOx budget unit which specifies the NOx Budget Trading Program requirements applicable to a NOx budget source, to each NOx budget unit at the NOx budget source, and to the owners and operators and the NOx authorized account representative of the NOx budget source and each NOx budget unit.
(52) NOx budget source. A source that includes one or more NOx budget units.
(53) NOx Budget Trading Program. A multi-state nitrogen oxides air pollution control and emission reduction program established pursuant to this Part, corresponding regulations in other states promulgated in accordance with 40 CFR 51.121, and federal implementation plans promulgated in accordance with 40 CFR part 97 as a means of mitigating the interstate transport of ozone and nitrogen oxides, an ozone precursor.
(54) NOx budget unit. A unit that is subject to NOx Budget Trading Program requirements under section 204-1.4 of this Subpart or section 204-9.1 of this Part.
(55) Operating. With regard to a unit under section 204-9.1 of this Part, having documented heat input or clinker production for more than 876 hours in the 6 months immediately preceding the submission of an application for a NOx budget permit under Section 204-9.4(a) of this Part.
(56) Operator. Any person who operates, controls, or supervises a NOx budget unit, a NOx budget source, or unit for which an application for a NOx budget opt-in permit under section 204-9.4 of this Part is submitted and not denied or withdrawn and shall include, but not be limited to, any holding company, utility system, or plant manager of such a unit or source.
(57) Opt-in. To be elected to become a NOx budget unit under the NOx Budget Trading Program through a final, effective NOx budget opt-in permit under Subpart 204-9 of this Part.
(58) Overdraft account. The NOx allowance tracking system account, established by the administrator under Subpart 204-6 of this Part, for each NOx budget source where there are two or more NOx budget units.
(59) Owner. Any of the following persons:
(i) any holder of any portion of the legal or equitable title in a NOx budget unit or in a unit for which an application for a NOx budget opt-in permit under section 204-9.4 of this Part is submitted and not denied or withdrawn;
(ii) any holder of a leasehold interest in a NOx budget unit or in a unit for which an application for a NOx budget opt-in permit under section 204-9.4 of this Part is submitted and not denied or withdrawn;
(iii) any purchaser of power from a NOx budget unit or from a unit for which an application for a NOx budget opt-in permit under section 204-9.4 of this Part is submitted and not denied or withdrawn under a life-of-the-unit, firm power contractual arrangement. However, unless expressly provided for in a leasehold agreement, owner shall not include a passive lessor, or a person who has an equitable interest through such lessor, whose rental payments are not based, either directly or indirectly, upon the revenues or income from the NOx budget unit or the unit for which an application for a NOx budget opt-in permit under section 204-9.4 of this Part is submitted and not denied or withdrawn; or
(iv) with respect to any general account, any person who has an ownership interest with respect to the NOx allowances held in the general account and who is subject to the binding agreement for the NOx authorized account representative to represent that person's ownership interest with respect to NOx allowances.
(60) Portland cement kiln. A system, including any solid, gaseous or liquid fuel combustion equipment, used to calcine and fuse raw materials, including limestone and clay, to produce portland cement clinker.
(61) Precalciner kiln. A kiln where the feed to the kiln system is preheated in cyclone chambers and utilizes a second burner to calcine material in a separate vessel attached to the preheater prior to the final fusion in a kiln which forms clinker.
(62) Preheater kiln. A kiln where the feed to the kiln system is preheated in cyclone chambers prior to the final fusion in a kiln which forms clinker.
(63) Preheater/precalciner kiln. A pyroprocessing system comprised of three main units, a preheater followed by a precalciner followed by a kiln. The preheater dries and preheats the feed in a series of cyclone vessels. The precalciner begins the calcination of the feed in a separate vessel. The kiln completes the calcination and sintering of the feed to produce clinker.
(64) Receive or receipt of. When referring to the department or the administrator, to come into possession of a document, information, or correspondence (whether sent in writing or by authorized electronic transmission), as indicated in an official correspondence log, or by a notation made on the document, information, or correspondence, by the department or the administrator in the regular course of business.
(65) Recordation, record, or recorded. With regard to NOx allowances, the movement of NOx allowances by the administrator from one NOx allowance tracking system account to another, for purposes of allocation, transfer, or deduction.
(66) Reference method. Any direct test method of sampling and analyzing for an air pollutant as specified in appendix A of 40 CFR part 60.
(67) Renewable energy project. A power generation technology that produces electricity from wind energy, solar thermal energy, photovoltaics, methane waste, or sustainably managed biomass; but not the combustion or pyrolysis of solid waste.
(68) Serial number. When referring to NOx allowances, the unique identification number assigned to each NOx allowance by the administrator under section 204-6.4(c) of this Part.
(69) Source. Any governmental, institutional, commercial, or industrial structure, installation, plant, building, or facility that emits or has the potential to emit any regulated air pollutant under the act. For purposes of section 502(c) of the act, a source, including a source with multiple units, shall be considered a single facility.
(70) State. One of the 48 contiguous states and the District of Columbia, or any non-federal authority in or including such states or the District of Columbia (including local agencies, and statewide agencies) or any eligible Indian tribe in an area of such state or the District of Columbia, that establishes a corresponding regulation as part of the NOx Budget Trading Program.
(71) State trading program budget. The total number of NOx tons apportioned to all NOx budget units in a given state, in accordance with the NOx Budget Trading Program, for use in a given control period.
(72) Submit or serve. To send or transmit a document, information, or correspondence to the person specified in accordance with the applicable regulation:
(i) in person;
(ii) by United States Postal Service; or
(iii) by other means of dispatch or transmission and delivery.
Compliance with any submission, service, or mailing deadline shall be determined by the date of dispatch, transmission, or mailing and not the date of the receipt.
(73) Thermal efficiency. The ratio of energy output (in Btu) to energy input (in Btu) based on the higher heating value heat content of the fuel.
(74) Ton or tonnage. Any short ton (i.e., 2,000 pounds). For the purpose of determining compliance with the NOx budget emissions limitation, total tons for a control period shall be calculated as the sum of all recorded hourly emissions (or the tonnage equivalent of the recorded hourly emissions rates) in accordance with Subpart 204-8 of this Part, with any remaining fraction of a ton equal to or greater than 0.50 ton deemed to equal one ton and any fraction of a ton less than 0.50 ton deemed to equal zero ton.
(75) Unit. A fossil fuel-fired stationary boiler, combustion turbine, combined cycle system, or portland cement kiln.
(76) Unit operating day. A calendar day in which a unit combusts any fuel.
(77) Unit operating hour or hour of unit operation. Any hour (or fraction of an hour) during which a unit combusts any fuel.
§204-1.3 Measurements, abbreviations, and acronyms
Measurements, abbreviations, and acronyms used in this Part are defined as follows:
(a) Btu-British thermal unit.
(b) hr-hour.
(c) Kwh-kilowatt hour.
(d) lb-pounds.
(e) mmBtu-million Btu.
(f) MWe-megawatt electrical.
(g) CO2-carbon dioxide.
(h) NOx-nitrogen oxides.
(i) O2-oxygen.
§204-1.4 Applicability
(a) The following units shall be NOx budget units, and any source that includes one or more such units shall be a NOx budget source, subject to the requirements of this Part:
(1) Electricity generating units. Any unit that, any time on or after January 1, 1995, serves a generator with a nameplate capacity equal to or greater than 15 MWe and sells any amount of electricity.
(2) Portland cement kiln units. Any unit that is a portland cement kiln having a maximum design heat input equal to or greater than 250 mmBtu/hr.
(3) Non-electricity generating units. Any unit other than an electricity generating unit or a portland cement kiln unit under paragraph (1) or (2) of this subdivision, respectively, which has a maximum design heat input equal to or greater than 250 mmBtu/hr.
(b) Limited exemption for certain NOx budget units. Notwithstanding subdivision (a) of this section, a NOx budget unit under paragraph (a)(1) or (3) of this section shall be subject only to the requirements of this subdivision if the unit has a permit that meets the requirements of paragraph (1) of this subdivision and restricts the unit to burning only natural gas or fuel oil during a control period in 2003 or later and each control period thereafter and restricts the unit's operating hours during each such control period to the number of hours (determined in accordance with subparagraphs (1)(ii) and (iii) of this subdivision that limits the unit's potential NOx mass emissions for the control period to 25 tons or less.
(1) For each control period under this subdivision, the permit must:
(i) restrict the unit to burning only natural gas or fuel oil;
(ii) restrict the unit's operating hours to the number calculated by dividing 25 tons of potential NOx mass emissions by the unit's maximum potential hourly NOx mass emissions;
(iii) require that the unit's potential NOx mass emissions shall be calculated as follows:
(a) select the default NOx emission rate in table LM-2 of 40 CFR 75.19(c)(1)(ii) that would otherwise be applicable assuming that the unit burns only the type of fuel (i.e., only natural gas or only fuel oil) that has the highest default NOx emission factor of any type of fuel that the unit is allowed to burn under the fuel use restriction in subparagraph (i) of this paragraph; and
(b) multiply the default NOx emission rate under clause (a) of this subparagraph by the unit's maximum rated hourly heat input. The owner or operator of the unit may petition the department to use a lower value for the unit's maximum rated hourly heat input than the value as defined under section 204-1.2 of this Subpart. The department may approve such lower value if the owner or operator demonstrates that the maximum hourly heat input specified by the manufacturer or the highest observed hourly heat input, or both, are not representative, and that such lower value is representative, of the unit's current capabilities because modifications have been made to the unit, limiting its capacity permanently;
(iv) require that the owner or operator of the unit shall retain at the source that includes the unit, for 5 years, records demonstrating that the operating hours restriction, the fuel use restriction, and the other requirements of the permit related to these restrictions were met; and
(v) require that the owner or operator of the unit shall report the unit's hours of operation (treating any partial hour of operation as a whole hour of operation) during each control period to the department by November 1st of each year.
(2) The department will notify the administrator in writing of each unit under subdivision (a) of this section whose permit contains the fuel use restriction under subparagraph (1)(i) of this subdivision and the operating hours restriction under subparagraphs (1)(ii) and (iii) of this subdivision. The department will also notify the administrator in writing of each unit under subdivision (a) of this section whose permit is revised to remove any such restriction, whose permit includes any such restriction that is no longer applicable, or which does not comply with any such restriction.
(3) If, for any control period under subdivision, the fuel use restriction under subparagraph (1)(i) of this subdivision or the operating hours restriction under subparagraphs (1)(ii) and (iii) of this subdivision is removed from the unit's permit or otherwise becomes no longer applicable or if, for any such control period, the unit does not comply with the fuel use restriction under subparagraph (1)(i) of this subdivision or the operating hours restriction under subparagraphs (1)(ii) and (iii) of this subdivision, the unit shall be subject to all applicable requirements of this Part.
§204-1.5 Shutdown or change in physical characteristics of a NOx budget unit
(a) Any NOx budget unit that is permanently shutdown and has surrendered its permit will no longer be deemed a NOx budget unit and shall no longer be subject to the provisions of this Part applicable to NOx budget units on the day on which the procedures set forth in paragraph (c)(1) of this section are completed.
(b) Any NOx budget unit, other than a NOx budget opt-in unit, that has permanently changed its physical characteristics so that it no longer fits the physical description of a NOx budget unit under 204-1.4(a) of this Subpart (for example, a non-electricity generating unit completes a physical plant change which reduces its maximum design heat input to below 250 mmBtu/hr) will no longer be deemed a NOx budget unit and shall no longer be subject to the provisions of this Part applicable to NOx budget units on the day on which the procedures set forth in paragraph (c)(2)of this section are completed.
(c) (1) The NOx authorized account representative submits a statement to the department (in a format prescribed by the department) attesting to the fact that the unit is permanently shutdown and that the unit's permit has been surrendered to the department. A copy of the statement must simultaneously be submitted to the administrator.
(2) The NOx authorized account representative submits a statement to the department (in a format prescribed by the department) and the administrator attesting to the fact that the physical characteristics of the unit have been permanently changed so that it no longer fits the physical description of a NOx budget unit under section 204-1.4(a) of this Subpart. This statement must be accompanied by adequate information which details the changes to the physical characteristics of the unit. The department, in consultation with the administrator, will then determine whether the statement is valid. Upon the department's determination that the statement is valid, the procedures of this paragraph are completed.
(d) Any NOx budget unit which ceases to be deemed a NOx budget unit pursuant to this section is not eligible for an allocation or distribution of NOx allowances pursuant to Subpart 204-5 of this Part following the completion of the procedures set forth in paragraph (c)(1) or (2) of this section.
§204-1.6 Standard requirements
(a) Permit requirements. (1) The NOx authorized account representative of each NOx budget unit shall:
(i) submit to the department a complete NOx budget permit application under section 204-3.3 of this Part in accordance with the deadlines specified in section 204-3.2(b) of this Part; and
(ii) submit in a timely manner any supplemental information that the department determines is necessary in order to review a NOx budget permit application and issue or deny a NOx budget permit.
(2) The owners and operators of each NOx budget unit shall have a NOx budget permit and operate the unit in compliance with such NOx budget permit.
(b) Monitoring requirements. (1) The owners and operators and, to the extent applicable, the NOx authorized account representative of each NOx budget source and each NOx budget unit at the source shall comply with the monitoring requirements of Subpart 204-8 of this Part.
(2) The emissions measurements recorded and reported in accordance with Subpart 204-8 of this Part shall be used to determine compliance by the unit with the NOx budget emissions limitation under subdivision (c) of this section.
(c) Nitrogen oxides requirements. (1) The owners and operators of each NOx budget source and each NOx budget unit at the source shall hold NOx allowances available for compliance deductions under section 204-6.5 of this Part, as of the NOx allowance transfer deadline, in the unit's compliance account and the source's overdraft account in an amount not less than the total NOx emissions for the control period from the unit, as determined in accordance with Subpart 204-8 of this Part.
(2) Each ton of nitrogen oxides emitted in excess of the NOx budget emissions limitation shall constitute a separate violation of this Part, the act, and applicable State law.
(3) A NOx budget unit shall be subject to the requirements under paragraph (1) of this section starting on the later of May 1, 2003 or the date on which the unit commences operation.
(4) NOx allowances shall be held in, deducted from, or transferred among NOx allowance tracking system accounts in accordance with Subparts 204-5, 204-6, 204-7, and 204-9 of this Part.
(5) A NOx allowance shall not be deducted, in order to comply with the requirements under paragraph (1) of this subdivision, for a control period in a year prior to the year for which the NOx allowance was allocated.
(6) A NOx allowance allocated by the department under the NOx Budget Trading Program is a limited authorization to emit one ton of nitrogen oxides in accordance with the NOx Budget Trading Program. No provision of the NOx Budget Trading Program, the NOx budget permit application, or the NOx budget permit and no provision of law shall be construed to limit the authority of the United States or the State to terminate or limit such authorization.
(7) A NOx allowance allocated by the department under the NOx Budget Trading Program does not constitute a property right.
(d) Excess emissions requirements. The owners and operators of a NOx budget unit that has excess emissions in any control period shall:
(1) forfeit the NOx allowances required for deduction under section 204-6.5(d)(1) of this Part; and
(2) pay any fine, penalty, or assessment or comply with any other remedy imposed under section 204-6.5(d)(3) of this Part.
(e) Recordkeeping and reporting requirements. (1) Unless otherwise provided, the owners and operators of the NOx budget source and each NOx budget unit at the source shall keep on site at the source each of the following documents for a period of five years from the date the document is created. This period may be extended for cause, at any time prior to the end of five years, in writing by the department or the administrator.
(i) The account certificate of representation for the NOx authorized account representative for the source and each NOx budget unit at the source and all documents that demonstrate the truth of the statements in the account certificate of representation, in accordance with section 204-2.4 of this Part; provided that the certificate and documents shall be retained on site at the source beyond such five-year period until such documents are superseded because of the submission of a new account certificate of representation changing the NOx authorized account representative.
(ii) All emissions monitoring information, in accordance with Subpart 204-8 of this Part; provided that to the extent that Subpart 204-8 of this Part provides for a three year period for recordkeeping, the three year period shall apply.
(iii) Copies of all reports, compliance certifications, and other submissions and all records made or required under the NOx Budget Trading Program.
(iv) Copies of all documents used to complete a NOx budget permit application and any other submission under the NOx Budget Trading Program or to demonstrate compliance with the requirements of the NOx Budget Trading Program.
(2) The NOx authorized account representative of a NOx budget source and each NOx budget unit at the source shall submit the reports and compliance certifications required under the NOx Budget Trading Program, including those under Subpart 204-4, 204-8, or 204-9 of this Part.
(f) Liability. (1) No permit revision shall excuse any violation of the requirements of the NOx Budget Trading Program that occurs prior to the date that the revision takes effect.
(2) Any provision of the NOx Budget Trading Program that applies to a NOx budget source (including a provision applicable to the NOx authorized account representative of a NOx budget source) shall also apply to the owners and operators of such source and of the NOx budget units at the source.
(3) Any provision of the NOx Budget Trading Program that applies to a NOx budget unit (including a provision applicable to the NOx authorized account representative of a NOx budget unit) shall also apply to the owners and operators of such unit. Except with regard to the requirements applicable to units with a common stack under Subpart 204-8 of this Part, the owners and operators and the NOx authorized account representative of one NOx budget unit shall not be liable for any violation by any other NOx budget unit of which they are not owners or operators or the NOx authorized account representative and that is located at a source of which they are not owners or operators or the NOx authorized account representative.
(g) Effect on other authorities. No provision of the NOx Budget Trading Program, a NOx budget permit application, or a NOx budget permit, shall be construed as exempting or excluding the owners and operators and, to the extent applicable, the NOx authorized account representative of a NOx budget source or NOx budget unit from compliance with any other provisions of applicable State and Federal laws and regulations.
§204-1.7 Computation of time
(a) Unless otherwise stated, any time period scheduled, under the NOx Budget Trading Program, to begin on the occurrence of an act or event shall begin on the day the act or event occurs.
(b) Unless otherwise stated, any time period scheduled, under the NOx Budget Trading Program, to begin before the occurrence of an act or event shall be computed so that the period ends the day before the act or event occurs.
(c) Unless otherwise stated, if the final day of any time period, under the NOx Budget Trading Program, falls on a weekend or a State or Federal holiday, the time period shall be extended to the next business day.