Dunbar Compressor Station

The Dunbar Compressor Station located in Windsor, NY, will compress natural gas so that it can be connected and distributed to the Millenium Pipeline. The first link below will take you to the Division of Air's webpage for Draft Air State Facility Permits where you can view the draft permit. The list of conditions may be viewed either in the table below or by clicking on the second link.

Citation Pollutant Limit Averaging period Emission Unit Test Method Test Frequency Reporting Frequency
201-7 VOC 0.27 gm/hp-hr 3, 1-hr runs DC061,062,063 320 every 3 years per occurrence
201-7 VOC 0.20 gm/hp-hr 3, 1-hr runs DC161 320 every 3 years per occurrence
201-7 HCHO 0.0056 gm/hp-hr 0.059 lb/hr 3 runs DC161 320 every 3 years per occurrence
201-7 HCHO

0.0076 gm/hr-hr 0.029 lb/hr

3 runs DC 061, 062, 063 320 every 3 years per occurrence
201-7 HAP 24.5 tons/yr 12 month rolling period Facility Emission factors, Gly-Cal quarterly gas sampling annual
201-7 VOC 49 tons/yr 12 month rolling period Facility Emission factors, Gly-Cal quarterly gas sampling annual
201-7 HAP 9.5 tons/yr 12 month rolling period Facility Emission factors, Gly-Cal quarterly gas sampling annual
201-7 CO 0.06 gm/hp-hr 3, 1-hr runs Comp 320 every 3 years per occurrence
201-7 NOx 0.50 gm/hp-hr 3, 1-hr runs Comp 320 every 3 years per occurrence
NSPS JJJJ CO 2.0 gm/hp-hr1 3, 1-hr runs Comp 320 every 3 years per occurrence
NSPS JJJJ VOC 0.70 gm/hp-hr exclude HCHO1 3, 1-hr runs Comp 320 every 3 years per occurrence
NSPS JJJJ NOx 1.0 gm/hp-hr1 3, 1-hr runs Comp 320 every 3 years per occurrence
212.4 C6H6 460 lb/yr 12 month rolling period Comp Gly-Cal quarterly gas sampling annual
HH area Benzene 0.9 mg/yr 12 month Each Dehy Gly Calc or direct measurement annual annual