Region 6 SEQR and Other Notices Region 6 SPDES Renewals

ENB Region 6 Completed Applications 07/27/2005

Herkimer County

Applicant: Mark Slavin
Facility: Slavin Property on Third Lake
Old Boy Scout Rd
Webb, NY
Application ID: 6-2154-00272/00003
Permit(s) Applied for: Section 401 - Clean Water Act Water Quality Certification
Article 15 Title 5 Excavation & Fill in Navigable Waters
Project is Located: Herkimer County
Project Description:
The applicant proposes to rip-rap 150 feet of shoreline on the south shore of Third Lake. Field Biologist have visited the site and found significant erosion.The project will protect the shoreline in front of a seasonal residence.
State Environmental Quality Review (SEQR) Determination:
Project is an Unlisted Action and will not have a significant impact on the environment. A Negative Declaration is on file. A coordinated review was not performed.
SEQR Lead Agency:
None Designated
State Historic Preservation Act (SHPA) Determination:
Cultural resource lists and map have been checked. No registered, eligible or inventoried archaeological sites or historic structures were identified at the project location. No further review in accordance with SHPA is required.
Coastal Management:
This project is not located in a Coastal Management area and is not subject to the Waterfront Revitalization and Coastal Resources Act.
Opportunity for Public Comment:
Comments on this project must be submitted in writing to the Contact Person no later than Aug 12 2005.
Contact: Patrick M Clearey
NYSDEC Region 6 Utica SUB-OFFICE
State Office Bldg - 207 Genesee St
Utica, NY 13501
(315)793-2555
r6dep@gw.dec.state.ny.us

Jefferson County

Applicant: Katherine A Tremont
Facility: Tremont Outer Holcomb Street Property
Outer Holcomb ST|200' South of Marra Dr
Watertown, NY 13601
Application ID: 6-2218-00101/00001
Permit(s) Applied for: Article 24 Freshwater Wetlands
Section 401 - Clean Water Act Water Quality Certification
Project is Located: Jefferson County
Project Description:
The applicant proposes to construct a 50' x 70' single family residence on outer Holcomb Street in the City of Watertown.  The site is two lots southwest of Marra Drive.  The site borders regulated freshwater wetland W-2, a 339 acre Class II predominately emergent marsh wetland, with borders of wooded wetland.  Sewer and water will be obtained from the City of Watertown.  The residence would be constructed approximately 50' from the wetland.
State Environmental Quality Review (SEQR) Determination:
Project is an Unlisted Action and will not have a significant impact on the environment. A Negative Declaration is on file. A coordinated review was not performed.
SEQR Lead Agency:
None Designated
State Historic Preservation Act (SHPA) Determination:
Cultural resource lists and map have been checked. No registered, eligible or inventoried archaeological sites or historic structures were identified at the project location. No further review in accordance with SHPA is required.
Coastal Management:
This project is not located in a Coastal Management area and is not subject to the Waterfront Revitalization and Coastal Resources Act.
Opportunity for Public Comment:
Comments on this project must be submitted in writing to the Contact Person no later than Aug 12 2005.
Contact: Mark A Wiggins
NYSDEC Region 6 Headquarters
State Office BUILDING|317 Washington St
Watertown, NY 13601
(315)785-2245
r6dep@gw.dec.state.ny.us

Applicant: Town of Cape Vincent
1964 NYS Route 12-E
Cape Vincent, NY 13618
Facility: Cape Vincent Water District # 5
Co Rte 9 & Co Rte 4|ST Lawrence Corners
Cape Vincent, NY 13618
Application ID: 6-2228-00536/00001
Permit(s) Applied for: Article 24 Freshwater Wetlands
Section 401 - Clean Water Act Water Quality Certification
Article 15 Title 15 Water Supply
Project is Located: Jefferson County
Project Description:
The project is a water supply permit application by the Town of Cape Vincent for Cape Vincent Water District #5. They propose to take up to 25,675 gpd from Cape Vincent Water District #1 which receives its water supply from the Village of Cape Vincent. The proposed water distribution system would consist of approximately 6,000 LF of 8 inch diameter and 12,000 LF of 10 inch diameter Ductile Iron Pipe (DIP) water mains, 800 LF of 1 inch diameter and 900 LF of 3/4 inch diameter copper service laterals, 44 water service meters, 18 fire hydrants and one master meter.
State Environmental Quality Review (SEQR) Determination:
Project is an Unlisted Action and will not have a significant impact on the environment. A Negative Declaration is on file. A coordinated review was performed.
SEQR Lead Agency:
Cape Vincent Town Board
State Historic Preservation Act (SHPA) Determination:
Cultural resource lists and map have been checked. No registered, eligible or inventoried archaeological sites or historic structures were identified at the project location. No further review in accordance with SHPA is required.
Coastal Management:
This project is not located in a Coastal Management area and is not subject to the Waterfront Revitalization and Coastal Resources Act.
Opportunity for Public Comment:
Comments on this project must be submitted in writing to the Contact Person no later than Aug 12 2005.
Contact: Lawrence R Ambeau
NYSDEC Region 6 Headquarters
State Office BUILDING|317 Washington St
Watertown, NY 13601
(315)785-2245
r6dep@gw.dec.state.ny.us

Region 6 SEQR and Other Notices Region 6 SPDES Renewals