ENB Region 4 Completed Applications 03/08/00

Delaware County
 
Applicant: Nys Dept Of Transportation
1220 Washington Ave
Albany, NY 12232
Office: NYS DEC
Route 10
Stamford, NY 12167
(607) 652-7741
Contact: Christopher M. Hogan
SEQR: Project is an unlisted action and will not have a significant effect on the environment. A Negative Declaration is on file. No coordinated review was performed.
SHPA: Cultural resource lists and map have been checked. No registered, eligible or inventoried archaeological sites or historic structures were identified at the project location. No further review in accordance with SHPA is required
Last Filing Date: 03/24/2000
Project Location: Kortright
Project Description:
The applicant proposes to rehabilitate 4.1 miles of State Route 10 in the Town of Kortright. The project includes the replacement of two bridges and permanent impacts to 1.28 acres of wetland due to roadway realignments.
Permit: Section 401 - Clean Water Act: Water Quality Certification
Permit ID:DEC-4-1240-00113/00001

Rensselaer County
 
Applicant: Telergy Corp
1 Telergy Pkwy
East syracuse, NY 13057
Office: NYS DEC
1150 No. Westcott Rd.
Schenectady, NY 12306
(518) 357-2069
Contact: Arthur N. Henningson
SEQR: Project is a Type I action and will not have a significant effect on the environment. A Negative Declaration is on file and a coordinated review with other agencies has been performed.
SHPA: A Structural-Archaeological Assessment Form has been completed. The proposed activity will not have any impact on registered, eligible or inventoried archaeological sites or historic structures. No further review in accordance with SHPA is required.
Last Filing Date: 03/24/2000
Project Location:
Project Description:
Fiber Optic Cable Rensselaer to Hancock MA
Permit: Article 24: Freshwater Wetlands
Article 15, Title 5: Stream Protection
Section 401 - Clean Water Act: Water Quality Certification
Permit ID:DEC-4-3899-00021/00001

Schenectady County
 
Applicant: U S Dept Of Energy
1000 Independence Ave Sw
Washington, DC 20585
Office: NYS DEC
1150 No. Westcott Rd.
Schenectady, NY 12306
(518) 357-2069
Contact: Angelo A. Marcuccio
SEQR: Project is an unlisted action and will not have a significant effect on the environment. A Negative Declaration is on file. No coordinated review was performed.
SHPA: Cultural resource lists and map have been checked. No registered, eligible or inventoried archaeological sites or historic structures were identified at the project location. No further review in accordance with SHPA is required
Last Filing Date: 04/07/2000
Project Location: Niskayuna
Project Description:
The department has received an Air State Facility permit application for the Knolls Atomic Power Lab facility which is owned by the U.S. Dept. of Energy and is located on 2401 River Road in the Town of Niskayuna. The principal function of the facility is research & development in the design and operation of naval nuclear propulsion plants. The facility includes laboratories, machine shops, administrative offices, wastewater treatment and oil storage facilities, cooling towers, a sewage pumping station, waste storage facilities & a boiler house. This application involves the construction of a new boiler house to be located adjacent to the existing boiler house & the installation of 3 new firetube boilers to generate steam for the facility. Each boiler will have a heat input level of 35 million Btu per hour (mmBtu/hr). The existing boiler house contains 4 watertube boilers with 3 of the boilers having a heat input level of 34 mmBtu/hr & 1 boiler with a level of 11.2 mmBtu/hr. Once the new boilers are on line and functioning properly the existing boilers will be taken out of operation. In order to remain below the Title V & New Source Review applicability thresholds the appicant has proposed to restrict the potential to emit through enforceable permit conditions which will limit or cap emissions at a level which is less than 100 tons per year each for carbon monoxide, sulfur dioxide & oxides of nitrogen. The emission caps will be accomplished by placing the new boilers under the caps for the existing boilers which limit fuel usage & total Btu heat input. The applicant will be required to maintain records & report these data to verify compliance with the permit limits & condtions. By accept- ing these enforceable limits the facility will not be subject to Title V permitting or New Source Review requirements.
Permit: Article 19: Air State Facility Permit
Permit ID:DEC-4-4224-00024/00039