Network Plan Part 8 - Southern Monitoring Operation Site Descriptions (continued)
Holtsville

Address: Sagamore Junior High School
57 Division Street
Holtsville, NY 11742
AQS Number: 36-103-0009
DEC Number: 5151-10
New York State County: Suffolk
Statistical Area: New York City Metropolitan Area
Coordinates: 40.82799 N -73.05754 W
The Holtsville air monitoring station was established by the Suffolk County Department of Health Services - Division of Environmental Quality in the late 1990s. The Department established an ozone analyzer at the site during the 2006 ozone season. In June of 2010 the Department took over control of the site, following personnel changes in the Suffolk County Department of Health Services. The Department expanded its monitoring by added sulfur dioxide and fine particulate matter.
The parameters monitored and certified by NYS DEC are indicated in the following table:
| Parameter | Sampling Method | Analysis Method | Schedule |
|---|---|---|---|
| Ozone | TEI 49C Method 047 |
Ultraviolet Photometric |
Continuous (During NYS O3 Season) |
| Sulfur Dioxide | TEI 43C Method 060 |
Pulsed Fluorescence | Continuous |
| PM2.5 | Thermo Scientific TEOM 1405 Method 790 |
TEOM Gravimetric |
Continuous |
| Meteorological | MetOne Sonic Method 020 |
Continuous | |
| Barometric Pressure | MetOne Method 011 |
Continuous | |
| Relative Humidity | MetOne Method 011 |
Continuous | |
| Temperature | MetOne Method 040 |
Continuous |
IS 143

Address: New York City Department of Education
Junior High School 143
511 West 182nd Street
New York, NY 10033
AQS Number: 36-061-0115
DEC Number: 7093-15
County: New York
Statistical Area: New York City Metropolitan Area
Coordinates: 40.84888 N -73.93059 W
The IS143 site was established in 2000 as a continuous fine particulate (PM2.5) monitoring site. The site utilizes a R&P Tapered Element Oscillating Microbalance (TEOM). This site is located in an urbanized, residential area of Manhattan. Data from this site are reported to AIRNow.
The parameters monitored are indicated in the following table:
| Parameter | Sampling Method | Analysis Method | Schedule |
|---|---|---|---|
| PM2.5 | R&P TEOM 1400 Method 701 Method 702 |
TEOM 50°C Gravimetric |
Continuous |
IS 52

Address: New York City Department of Education
Public School 52/Middle School 302
681 Kelly Street
Bronx, NY 10455
AQS Number: 36-005-0110
DEC Number: 7094-07
County: Bronx
Statistical Area: New York City Metropolitan Area
Coordinates: 40.8162 N -73.9020 W
This site was established in 1999 as a replacement site for Public School 155. Initially the site contained ozone, oxides of nitrogen, sulfur dioxide, continuous PM2.5 and continuous PM10. Following an upgrade of the electricity, additional monitoring parameters were added, creating one of the premier particulate sampling sites in New York City. The site contains criteria pollutant parameters and
Methods along with many experimental
Methods.
This site has been temporarily shut down in June 2010 due to extensive construction at the school. The monitoring for NATTS parameters was moved to Morrisania II during that period. This site is now back to full operation.
The parameters normally monitored are indicated in the following table:
| Parameter | Sampling Method | Analysis Method | Schedule |
|---|---|---|---|
| Ozone | TEI 49C Method 047 |
Ultraviolet Photometric |
Continuous |
| Oxides of Nitrogen | TEI 42C Method 074 |
Chemiluminescence | Continuous |
| PM2.5, PM10, PMcourse | Thermo Scientific 1405 DF FDMS |
TEOM Gravimetric 50°C |
Continuous |
| PM2.5 | Low volume FRM R&P 2025 Method 118 |
Gravimetric | Daily 1 day in 3a |
| PM2.5 Speciation | Met One SASS Method 811 |
XRF | 1 day in 3 |
| IMPROVE Sampler | IMPROVE | 1 day in 3 | |
| Carbon | URG 3000 Method 838 |
IMPROVE TOR | 1 day in 3 |
| PM10 | Low volume FRMb R&P 2025 Method 127 |
Gravimetric | 1 day in 6a |
| PM10 - Metals | Method 907 | ICPMS | 1 day in 6a |
| PM2.5 - Nitrate | Thermo Scientific 8400N | --- | Continuous |
| Sulfate | Thermo Scientific 5020i Sulfate Particulate |
Pulsed Florescence | Continuous |
| Black Carbon | Magee Scientific Aethalometer Method 866 |
Optical Absorption | Continuous |
| Elemental Carbon/ Organic Carbon |
Sunset Laboratory Method 5040 |
Thermal Optical | Semi-Continuous |
| Polycyclic Aromatic Hydrocarbons-PAH |
Tisch TE 5007 Method 118 |
GC/MS EPA/ERG Lab | 1 day in 6 |
| Toxics | Canister Method 150 |
GC/MS | 1 day in 6a |
| Carbonyl | DNPH tube Method 202 |
HPLC - Ultraviolet Absorption | 1 day in 6 |
| Chromium | ERG Method 921 |
EPA/ERG | 1 day in 6 |
a Collocated unit
IS 74

Address: New York City Department of Education
Intermediate School 74 (MS 201)
730 Bryant Avenue
Bronx, NY 10474
AQS Number: 36-005-0112
DEC Number: 7094-08
County: Bronx
Statistical Area: New York City Metropolitan Area
Coordinates: 40.81551 N -73.88553 W
The Intermediate School 74 site was established in 2000 as a continuous fine particulate (PM2.5) monitoring station. The site utilizes a R&P Tapered Element Oscillating Microbalance (TEOM). This site is located in an urbanized, residential area of the Hunts Point area of the Bronx. Data from this site are reported to AIRNow.
The parameters monitored are indicated in the following table:
| Parameter | Sampling Method | Analysis Method | Schedule |
|---|---|---|---|
| PM2.5 | R&P TEOM 1400 Method 702 |
TEOM 50°C Gravimetric |
Continuous |