Network Plan Part 8 - Southern Monitoring Operation Site Descriptions (continued)

Holtsville

Picture of Holtsville Air Monitor

Address: Sagamore Junior High School
57 Division Street
Holtsville, NY 11742

AQS Number: 36-103-0009
DEC Number: 5151-10
New York State County: Suffolk
Statistical Area: New York City Metropolitan Area
Coordinates: 40.82799 N -73.05754 W

The Holtsville air monitoring station was established by the Suffolk County Department of Health Services - Division of Environmental Quality in the late 1990s. The Department established an ozone analyzer at the site during the 2006 ozone season. In June of 2010 the Department took over control of the site, following personnel changes in the Suffolk County Department of Health Services. The Department expanded its monitoring by added sulfur dioxide and fine particulate matter.

The parameters monitored and certified by NYS DEC are indicated in the following table:

Parameter information for Holtsville
Parameter Sampling Method Analysis Method Schedule
Ozone TEI 49C
Method 047
Ultraviolet
Photometric
Continuous
(During NYS
O3 Season)
Sulfur Dioxide TEI 43C
Method 060
Pulsed Fluorescence Continuous
PM2.5 Thermo Scientific
TEOM 1405
Method 790
TEOM
Gravimetric
Continuous
Meteorological MetOne Sonic
Method 020
Continuous
Barometric Pressure MetOne
Method 011
Continuous
Relative Humidity MetOne
Method 011
Continuous
Temperature MetOne
Method 040
Continuous

IS 143

Picture of IS 143 Air Monitor

Address: New York City Department of Education
Junior High School 143
511 West 182nd Street
New York, NY 10033

AQS Number: 36-061-0115
DEC Number: 7093-15
County: New York
Statistical Area: New York City Metropolitan Area
Coordinates: 40.84888 N -73.93059 W

The IS143 site was established in 2000 as a continuous fine particulate (PM2.5) monitoring site. The site utilizes a R&P Tapered Element Oscillating Microbalance (TEOM). This site is located in an urbanized, residential area of Manhattan. Data from this site are reported to AIRNow.

The parameters monitored are indicated in the following table:

Parameter information for IS143
Parameter Sampling Method Analysis Method Schedule
PM2.5 R&P TEOM 1400
Method 701
Method 702
TEOM 50°C
Gravimetric
Continuous

IS 52

Picture of IS 52 Air Monitor

Address: New York City Department of Education
Public School 52/Middle School 302
681 Kelly Street
Bronx, NY 10455

AQS Number: 36-005-0110
DEC Number: 7094-07
County: Bronx
Statistical Area: New York City Metropolitan Area
Coordinates: 40.8162 N -73.9020 W

This site was established in 1999 as a replacement site for Public School 155. Initially the site contained ozone, oxides of nitrogen, sulfur dioxide, continuous PM2.5 and continuous PM10. Following an upgrade of the electricity, additional monitoring parameters were added, creating one of the premier particulate sampling sites in New York City. The site contains criteria pollutant parameters and
Methods along with many experimental
Methods.

This site has been temporarily shut down in June 2010 due to extensive construction at the school. The monitoring for NATTS parameters was moved to Morrisania II during that period. This site is now back to full operation.

The parameters normally monitored are indicated in the following table:

Parameter information for IS 52
Parameter Sampling Method Analysis Method Schedule
Ozone TEI 49C
Method 047
Ultraviolet
Photometric
Continuous
Oxides of Nitrogen TEI 42C
Method 074
Chemiluminescence Continuous
PM2.5, PM10, PMcourse Thermo Scientific
1405 DF FDMS
TEOM
Gravimetric 50°C
Continuous
PM2.5 Low volume FRM
R&P 2025
Method 118
Gravimetric Daily
1 day in 3
PM2.5 Speciation Ions and Elements Met One SASS
Method 811
IC, +XRF 1 day in 3
IMPROVE Sampler IMPROVE 1 day in 3
PM2.5 Speciation
Carbon
URG 3000
Method 838
IMPROVE TOR 1 day in 3
PM10 Low volume FRM
R&P 2025
Method 127
Gravimetric 1 day in 6a
PM10 - Metals Method 907 ICPMS 1 day in 6a
PM2.5 - Nitrate Thermo Scientific 8400N --- Continuous
Sulfate Thermo Scientific 5020i
Sulfate Particulate
Pulsed Florescence Continuous
Black Carbon Magee Scientific Aethalometer
Method 866
Optical Absorption Continuous
Elemental Carbon/
Organic Carbon
Sunset Laboratory
Method 5040
Thermal Optical Semi-Continuous
Polycyclic Aromatic
Hydrocarbons-PAH
Tisch TE 5007
Method 118
GC/MS EPA/ERG Lab 1 day in 6
Toxics Canister
Method 150
GC/MS 1 day in 6a
Carbonyl DNPH tube
Method 202
HPLC - Ultraviolet Absorption 1 day in 6
Wind Speed/direction Climatronics Method 020 Sonic Continuous

a Collocated unit

IS 74

Picture of IS 74 Air Monitor

Address: New York City Department of Education
Intermediate School 74 (MS 201)
730 Bryant Avenue
Bronx, NY 10474

AQS Number: 36-005-0112
DEC Number: 7094-08
County: Bronx
Statistical Area: New York City Metropolitan Area
Coordinates: 40.81551 N -73.88553 W

The Intermediate School 74 site was established in 2000 as a continuous fine particulate (PM2.5) monitoring station. The site utilizes a R&P Tapered Element Oscillating Microbalance (TEOM). This site is located in an urbanized, residential area of the Hunts Point area of the Bronx. Data from this site are reported to AIRNow.

The parameters monitored are indicated in the following table:

Parameter information for IS 74
Parameter Sampling Method Analysis Method Schedule
PM2.5 R&P TEOM 1400
Method 702
TEOM 50°C
Gravimetric
Continuous